CLIA Kit for N-Terminal Pro-Brain Natriuretic Peptide (NT-ProBNP)
MatrixRecovery range (%)Average(%)
serum(n=5)87-10197
EDTA plasma(n=5)78-10497
heparin plasma(n=5)84-10287
Request to COA Click Here

Description

Specificity

This assay has high sensitivity and excellent specificity for detection of N-Terminal Pro-Brain Natriuretic Peptide (NT-ProBNP).
No significant cross-reactivity or interference between N-Terminal Pro-Brain Natriuretic Peptide (NT-ProBNP) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant N-Terminal Pro-Brain Natriuretic Peptide (NT-ProBNP) and the recovery rates were calculated by comparing the measured value to the expected amount of N-Terminal Pro-Brain Natriuretic Peptide (NT-ProBNP) in samples.

MatrixRecovery range (%)Average(%)
serum(n=5)87-10197
EDTA plasma(n=5)78-10497
heparin plasma(n=5)84-10287

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level N-Terminal Pro-Brain Natriuretic Peptide (NT-ProBNP) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level N-Terminal Pro-Brain Natriuretic Peptide (NT-ProBNP) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of N-Terminal Pro-Brain Natriuretic Peptide (NT-ProBNP) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample1:21:41:81:16
serum(n=5)78-93%94-103%95-103%78-105%
EDTA plasma(n=5)78-89%96-103%97-105%95-104%
heparin plasma(n=5)96-103%91-98%80-93%79-89%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

ReagentsQuantityReagentsQuantity
Pre-coated, ready to use 96-well strip plate1Plate sealer for 96 wells4
Standard2Standard Diluent1×20mL
Detection Reagent A1×120µLAssay Diluent A1×12mL
Detection Reagent B1×120µLAssay Diluent B1×12mL
Substrate A1×10mLSubstrate B1×2mL
Wash Buffer (30 × concentrate)1×20mLInstruction manual1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Organism SpeciesHomo sapiens (Human)
Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Test MethodDouble-antibody Sandwich
Assay Length2h, 40min
Detection Range3.43-2,500pg/mL
SensitivityThe minimum detectable dose of this kit is typically less than 1.23pg/mL.
UOM48T | 96T | 96T*5 | 96T*10 | 96T*100

Additional information

Catalog No.

SCA485Hu

Pack Size

48T, 96T, 96T*10, 96T*100, 96T*5